- voltage measurement ±600V (maximum range display ±1200 v), current measurement via shunt, power, energy and capacity measurement of d.c. circuits
 - two-line LCD display with high contrast and built-in backlighting
 - possibility of displaying the measured value and time simultaneously or an second measured value or unit (automatically displayed unit of measured quantity)
 - wide range of voltage measurement at the shunt input up to 1500 mV
 - high sampling frequency of measured signals
 - programming parameters via buttons or rs-485 interface and free e-con software
 - 4 alarm outputs with signaling on led diodes, working in 7 different modes (option)
 - pulse output to control energy consumption
 - conversion of any measured value into an analog signal 0/4...20 mA or 0...10V (option).
 - memory of minimal and maximal values for all measured quantities.
 - automatic voltage measurement compensation function alarms
 - overall dimensions: 96 x 48 x 93 mm.
 